You can adjust the settings of your storage array, to modify how Site Recovery Manager and vCenter Server communicate with the storage replication adapter (SRA).

1

Click Sites in the left pane, right-click the site on which to change settings, and select Advanced Settings.

2

Click storage.

3

Modify the storage settings.

Option

Action

Change SRA update timeout

Type a new value in the storage.commandTimeout text box.

Change the maximum number of concurrent SRA operations

Type a new value in the storage.maxConcurrentCommandCnt text box.

Change the minimum amount of time in seconds between datastore group computations

Type a new value in the storage.minDsGroupComputationInterval text box.

Change the interval between status updates for ongoing data synchronization operations

Type a new value in the storage.querySyncStatusPollingInterval text box.

Change the interval between storage array discovery checks

Type a new value in the storage.storagePingInterval text box.

Change the maximum amount of time permitted for data synchronization operations to complete

Type a new value in the storage.syncTimeout text box.

4

Click OK to save your changes.