This VMware Validated Design requires that the following VLAN IDs and IP subnets be allocated for the traffic types in the SDDC.

According to the VMware Validated Design, you have the following VLANs and IP subnets in Region A.

VLAN and IP Subnet Configuration in Region A

Pod in Region A

VLAN Function

VLAN ID

Subnet

Gateway

Management Pod

ESXi Management

1611

172.16.11.0/24

172.16.11.253

vSphere vMotion

1612

172.16.12.0/24

172.16.12.253 

vSAN

1613

172.16.13.0/24

172.16.13.253

VXLAN (NSX VTEP)

1614

172.16.14.0/24

172.16.14.253

NFS

1615

172.16.15.0/24

172.16.15.253

vSphere Replication

vSphere Replication NFC

1616

172.16.16.0/24

172.16.16.253

Uplink01

2711

172.27.11.0/24

172.27.11.253

Uplink02

2712

172.27.12.0/24

172.27.12.253

External Management Connectivity

130

10.158.130.0/24

10.158.130.253

Shared Edge and Compute Pod

ESXi Management

1631

172.16.31.0/24

172.16.31.253

vSphere vMotion

1632

172.16.32.0/24

172.16.32.253

vSAN

1633

172.16.33.0/24

172.16.33.253

VXLAN (NSX VTEP)

1634

172.16.34.0/24

172.16.34.253

NFS

1625

172.16.25.0/24

172.16.25.253

Uplink01

1635

172.16.35.0/24

172.16.35.253

Uplink02

2713

172.27.13.0/24

172.27.13.253

External Tenant Connectivity

140

10.158.140.0/24

10.158.140.253

If you expand your design to two regions later, you have the following VLANs and IP subnets in Region B.

VLAN and IP Subnet Configuration in Region B 

Region B

VLAN Function

VLAN ID

Subnet

Gateway

Management Pod

ESXi Management

1711

172.17.11.0/24

172.17.11.253

vSphere vMotion

1712

172.17.12.0/24

172.17.12.253 

vSAN

1713

172.17.13.0/24

172.17.13.253

VXLAN (NSX VTEP)

1714

172.17.14.0/24

172.17.14.253

NFS

1715

172.17.15.0/24

172.17.15.253

vSphere Replication

vSphere Replication NFC

1716

172.17.16.0/24

172.17.16.253

Uplink01

2714

172.27.14.0/24

172.27.14.253

Uplink02

2715

172.27.15.0/24

172.27.15.253

External Management Connectivity

150

10.158.150.0/24

10.158.150.253

Shared Edge and Compute Pod

ESXi Management

1731

172.17.31.0/24

172.17.31.253

vSphere vMotion

1732

172.17.32.0/24

172.17.32.253

vSAN

1733

172.17.33.0/24

172.17.33.253

VXLAN (NSX VTEP)

1734

172.17.34.0/24

172.17.34.253

NFS

1725

172.17.25.0/24

172.17.25.253

Uplink01

1735

172.17.35.0/24

172.17.35.253

Uplink02

2721

172.27.21.0/24

172.27.21.253

External Tenant Connectivity

160

10.158.160.0/24

10.158.160.253

Note

These VLAN IDs and IP subnets are examples. The actual implementation depends on your environment.