Configure the NSX Manager for the management cluster and the NSX Manager for the compute and edge clusters to send audit logs and system events to vRealize Log Insight in Region A. 

1

On the Windows host that has access to the data center, log in to the NSX Manager Web interface.

a

Open a Web browser and go to following URL. 

NSX Manager

URL

NSX Manager for the management cluster

https://mgmt01nsxm01.sfo01.rainpole.local

NSX Manager for the shared compute and edge cluster

https://comp01nsxm01.sfo01.rainpole.local

b

Log in using the following credentials.

Setting

Value

User name

 admin

Password

 nsx_manager_admin_password

2

On the main page of the appliance user interface, click Manage Appliance Settings.

3

Under Settings, click General, and in the Syslog Server pane, click Edit.

4

In the Syslog Server dialog box, configure vRealize Log Insight as a syslog server by specifying the following settings and click OK.

Syslog Server Setting

Value

Syslog Server

vrli-cluster-01.sfo01.rainpole.local

Port

514

Protocol

UDP

5

Repeat the steps for the other NSX Manager.